Research use only. All compounds are for laboratory research. Not for human or veterinary use. 21+.

TB-500, 5 mg

Lot VA-2512-2631, analysed 2026-05-17

Traceability. The analytical report behind this certificate names the manufacturing lot, and the vials sold under VA-2512-2631 were filled from it. The lot identifier itself stays internal: it is shared with every brand the manufacturer fills for, and publishing it would let anyone match this material to a certificate issued under another name.

Results

TestSpecificationResultStatus
Appearance Visual inspection (Vantage Aminos)White lyophilized powderConformsPASS
Identity HPLC-UV-MS, positive polarity (+MS)Theoretical mass ± 1.0 Da4960.58 Da (theor. 4960.48)PASS
Purity HPLC-UV, area % · DAD 209.9-290.1 nm≥ 98.0 %98.32 %PASS
Quantity Quantitation as reported90-110 % of label (5 mg)5.237 mg (104.7 % of label)PASS
Largest single impurity HPLC-UV, area %Report1.54 % at 6.98 minREPORT
Water content Karl Fischer titration≤ 8 % w/w4.34 % w/wPASS

Open the certificate (PDF, opens in a new tab) Go to TB-500 All batch records

Identity and handling

Specimen readout VA-TB500-5MG
CAS
77591-33-4
FORMULA
C212H350N56O78S
MOL. WEIGHT
4963
SEQUENCE
Ac-Ser-Asp-Lys-Pro-Asp-Met-Ala-Glu-Ile-Glu-Lys-Phe-Asp-Lys-Ser-Lys-Leu-Lys-Lys-Thr-Glu-Thr-Gln-Glu-Lys-Asn-Pro-Leu-Pro-Ser-Lys-Glu-Thr-Ile-Glu-Gln-Glu-Lys-Gln-Ala-Gly-Glu-Ser
FORM
Lyophilized powder
FILL
5 mg
CONTAINER
3 mL vial
MANUFACTURED
2026-04-30
FILLED
2026-05-12
ANALYSED
2026-05-17
RETEST BY
2028-04-30
STORAGE
Refrigerated, 2-8 °C, protected from light
DOCUMENT
COA-VA-2512-2631 rev 1.1

Method

  • Technique Reverse-phase HPLC with UV detection, MS confirmation
  • Detection 209.9-290.1 nm (DAD range, not a single wavelength)
  • MS technique HPLC-UV-MS (as printed on certificate)
  • Ionisation Positive polarity (+MS)
  • Scan range m/z 497.7 - 2997.6 (as plotted)
  • Theoretical mass 4960.48 Da
  • Observed mass 4960.58 Da
  • Deviation +0.10 Da

Column, mobile phases, gradient, flow rate and injection volume are not stated on the laboratory report and are therefore not listed.

For research use only. Not for human or veterinary use. Not approved by the FDA. 21+