GLOW, 70 mg

Lot VA-2602-7527, analysed 2026-05-15

Traceability. The analytical report behind this certificate names the manufacturing lot, and the vials sold under VA-2602-7527 were filled from it. The lot identifier itself stays internal: it is shared with every brand the manufacturer fills for, and publishing it would let anyone match this material to a certificate issued under another name.

Results

TestSpecificationResultStatus
Appearance Visual inspection (Vantage Aminos)Blue to blue-green lyophilized powderConformsPASS
Identity , GHK-Cu HPLC-UV-MS, positive polarity (+MS)Theoretical mass ± 1.0 Da402.12 Da (theor. 402.10)PASS
Identity , BPC-157 HPLC-UV-MS, positive polarity (+MS)Theoretical mass ± 1.0 Da1418.77 Da (theor. 1418.70)PASS
Identity , TB-500 (thymosin β4 fragment 17-23) HPLC-UV-MS, positive polarity (+MS)Theoretical mass ± 1.0 Da888.54 Da (theor. 888.49)PASS
Purity HPLC-UV, area % · DAD 210.1-288.3 nm≥ 98.0 %99.81 %PASS
Quantity Quantitation as reported90-110 % of label (70 mg)71.003 mg (101.4 % of label)PASS
Largest single impurity HPLC-UV, area %Report0.18 % at 2.22 minREPORT
Water content Karl Fischer titration≤ 8 % w/w3.79 % w/wPASS

Open the certificate (PDF, opens in a new tab) Go to GLOW All batch records

Identity and handling

Specimen readout VA-GLOW70-70MG
FORM
Lyophilized powder
FILL
70 mg
CONTAINER
3 mL vial
MANUFACTURED
2026-04-17
FILLED
2026-05-12
ANALYSED
2026-05-15
RETEST BY
2028-04-17
STORAGE
Refrigerated, 2-8 °C, protected from light
DOCUMENT
COA-VA-2602-7527 rev 1.0

Method

  • Technique Reverse-phase HPLC with UV detection, MS confirmation
  • Detection 210.1-288.3 nm (DAD range, not a single wavelength)
  • MS technique HPLC-UV-MS (as printed on certificate)
  • Ionisation Positive polarity (+MS)
  • Scan range m/z 48.2 - 1997.5 (as plotted)
  • Theoretical mass 402.10 Da
  • Observed mass 402.12 Da
  • Deviation +0.02 Da

Column, mobile phases, gradient, flow rate and injection volume are not stated on the laboratory report and are therefore not listed.